System 800xA includes a comprehensive library of standard reusable components that include extended automation entities such as faceplates, graphic elements, trends, document links, and alarm and events. In addition, ABB provides a broad family of industry specific libraries that contain pre-configured Control Modules, Function Blocks, and graphic elements. These pre-tested proven libraries significantly reduce the time required to engineer, test, and maintain control applications, while minimizing project risks.
With more than 30 years of experience in designing, implementing, and maintaining safety systems, ABB provides a wide range of field proven applications, including
- Fire and Gas systems
- Emergency and Process shutdown (ESD and PSD)
- Interlock systems
- Burner Management and Boiler Protection (BMS)
- Critical Control
- High Pressure Protection Systems (HIPPS)
- Pipeline Protection systems (PPS)
Supervision Library
The Supervision library contains control module types for detector input, system control and monitoring, overview presentation and output handling. The modules are applicable for general detection systems as well as SIL applications. Certified for use in SIL2 marked applications.
SupervisionBasic Library
The SupervisonBasic library contains control module types for shutdown logic. Certified for use in SIL3 marked applications.
Burner Management Library (BMS)
The BMS library is TÜV certified and available for use with ABB or 3rd Party Process Control Systems. It helps to reduce engineering efforts and improves operation and maintenance of Burner Management applications. The new Burner Management System library is suitable for different fuel types and contains TÜV certified SIL 3 capable functions blocks for complete control over the startup and operation of burners including control and monitoring of the ignition sequence, leak testing of valves and control of the air/fuel mixture and the fuel supply.
Fire&Gas Library
The Fire&Gas library contain control module types for monitoring and control of protection systems that are typically used in a Fire&Gas system. All modules can be used in SIL classified applications. The Fire&Gas library use types from the Supervision library. This means that when you use the Fire&Gas library, the Supervision library has to be connected as well. Certified for use in SIL2 marked applications.
Communication Library
The communication libraries contain funcion block types and control module types for reading and writing variables from one system to another. The communication library for use in safety system is called MMS Communication Library. The function block types are to be used for non-safety critical functions and the control modules are to be used for communication between SIL marked applications (a certified link). Certified for use in SIL2 or SIL3 marked applications.
See more details in the User Manual 800xA - Safety, Safety Manual