You can view this page in:

 

Your country has been recognized as

United States

. Distributor Inventory search is not available for your location. If your location was recognized incorrectly, you can change it to another

English

speaking country.
Sorry your search did not return an exact match or there is no inventory available from our authorized distributors in your country. If you need further assistance, please contact our Contact Center

Detailed information for: XT1C 160 TMD 100-1000 3p F F

This page contains technical data sheet, documents library and links to offering related to this product. If you require any other information, please contact us using form located at the bottom of the page.

Data Sheet
Downloads
Where to buy online
Related Links

XT1C 160 TMD 100-1000 3p F F

General Information

  • Extended Product Type:
    XT1C 160 TMD 100-1000 3p F F
  • Product ID:
    1SDA067397R1
  • EAN:
    8015644012915
  • Catalog Description:
    XT1C 160 TMD 100-1000 3p F F
  • Long Description:
    C.BREAKER TMAX XT1C 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 100-1000 A

Ordering

  • Order Code US and Canada:
    XT1CE3100AFF000XXX
  • E-Number (Finland):
    3638777
  • EAN:
    8015644012915
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362090

Dimensions

  • Product Net Width:
    76.2 mm
  • Product Net Height:
    130 mm
  • Product Net Depth / Length:
    70 mm
  • Product Net Weight:
    1.1 kg

Container Information

  • Package Level 1 Units:
    box 1 piece
  • Package Level 1 Width:
    128 mm
  • Package Level 1 Height:
    135 mm
  • Package Level 1 Depth / Length:
    143 mm
  • Package Level 1 Gross Weight:
    1.136 kg
  • Package Level 1 EAN:
    8015644012915

Environmental

  • RoHS Status:
    Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • Conflict Minerals Reporting Template (CMRT):
    9AKK108467A5658
  • Environmental Information:
    9AKK107991A8215
    9AKK108467A6707
  • REACH Declaration:
    9AKK108466A1425
  • RoHS Information:
    9AKK108466A1424
  • SCIP:
    9965ca99-affa-4173-b6ec-86c5b94f7e15 Italy (IT)
  • Simplified SCIP:
    690bbaca-e914-49b1-b061-fadc8cb41754 Netherlands (NL)
    1d9c93da-ce2a-496b-963a-5aa10a5952ea Netherlands (NL)
    faccd3ac-7bd6-452b-b339-f3e8650b7ed7 Germany (DE)
    3971316a-abb7-4fb7-a3a4-b645aa241259 Denmark (DK)
    adf816cc-8afa-408f-b37f-84d38645b9ce Germany (DE)
    f57e9c1b-e394-43c6-92b6-24992fec4513 Croatia (HR)
    a23327a4-9935-4203-a9d5-741ba39df896 Czech Republic (CZ)
    b8b0676f-7b3e-4d5c-aa3c-7b6ebfe5bc3e Netherlands (NL)
    678300f8-ecd0-4b74-8804-18f219da3ae0 Netherlands (NL)
    2d166b04-bfde-406d-ae1b-a2d4f9a45c1f Estonia (EE)
    769c0bf8-bb50-4b05-90d1-f148493e2e93 Greece (GR)
    c222885d-c4e3-48f8-aa94-67f29ec03c2e Portugal (PT)
    0fa0c29c-f77e-4742-bd29-9f67a5dd58e7 Bulgaria (BG)
    3a1ec757-f5bc-4fe2-a796-b80d5848b865 Sweden (SE)
    3380a59b-f15a-4f8b-8fe2-54d228c70377 Poland (PL)
    25e84eae-96f0-42ce-9d7d-9dfb5f5ce2a5 France (FR)
    dafbc307-d434-4abc-8c03-c64d3fc1c333 Sweden (SE)
    3b414454-d89f-4090-bb59-470a3c7330ea Germany (DE)
    59695450-664d-4372-9510-6f5c4ac5ad03 Germany (DE)
    35ec2353-58cd-472a-b909-85aa064a6204 Spain (ES)
    95a1642c-9a73-4d2e-8a1b-c20ad5fc8a6c Netherlands (NL)
    5ec14cea-f544-4faa-ab16-fd3819a27732 Poland (PL)
    ca56bfe2-177d-4ed2-a416-d34db5ca5989 Poland (PL)
    37ce67d3-3a1a-4ca0-b8ae-7bf5eec07bd9 Finland (FI)
    3f937e08-97bb-4c73-ac98-fbbab57d1a84 Norway (NO)
    b394e0ce-ed58-41d4-9e52-9fc27c75e4e8 France (FR)
  • Toxic Substances Control Act - TSCA:
    9AKK108467A8326

Additional Information

  • Circuit Breaker Type to be Associated:
    Power Distribution
  • Connecting Capacity Main Circuit:
    Busbar 45.5 ... 80 mm²
  • Current Type:
    AC/DC
  • Electrical Durability:
    120 cycles per hour
    8000 cycle
  • Mechanical Durability:
    240 cycles per hour
    25000 cycle
  • Number of Poles:
    3
  • Opening Time:
    CB with SOR 15 ms
    CB with UVR 15 ms
  • Order Multiple:
    1 piece
  • Power Loss:
    at Rated Operating Conditions per Pole 7 W
  • Product Main Type:
    SACE Tmax XT
  • Product Name:
    Moulded Case Circuit Breaker
  • Product Type:
    Automatic Circuit Breaker
  • Rated Current (In):
    100 A
  • Rated Frequency (f):
    50 / 60 Hz
  • Rated Voltage (Ur):
    690 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Rated Instantaneous Short-Circuit Current Setting (Ii):
    1000 A
  • Rated Insulation Voltage (Ui):
    800 V
  • Rated Operational Voltage:
    690 V AC
    500 V DC
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    (220 V AC) 40 kA
    (230 V AC) 40 kA
    (240 V AC) 40 kA
    (380 V AC) 25 kA
    (415 V AC) 25 kA
    (440 V AC) 12.5 kA
    (500 V AC) 9 kA
    (525 V AC) 8 kA
    (690 V AC) 4 kA
    (250 V DC) 2 Poles in Series 25 kA
    (500 V DC) 3 Poles in Series 25 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    (220 V AC) 40 kA
    (230 V AC) 40 kA
    (240 V AC) 40 kA
    (380 V AC) 25 kA
    (415 V AC) 25 kA
    (440 V AC) 25 kA
    (500 V AC) 18 kA
    (525 V AC) 8 kA
    (690 V AC) 4 kA
    (250 V DC) 2 Poles in Series 25 kA
    (500 V DC) 3 Poles in Series 25 kA
  • Rated Uninterrupted Current (Iu):
    160 A
  • Recommended Screw Driver:
    Main Circuit M6
  • Release:
    TMD
  • Release Type:
    TM
  • RoHS Date:
    NA
  • Setting Range:
    70...100 A
  • Short-Circuit Performance Level:
    C
  • Standards:
    IEC
  • Sub-type:
    XT1
  • Terminal Connection Type:
    Front
  • Terminal Type:
    Bolt
  • Tightening Torque:
    6 N·m
  • Version:
    F
  • CAD Dimensional Drawing:
    1SDH001295R0008

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 5:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 6:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 7:
    EC000228 - Power circuit-breaker for trafo/generator/installation protection
  • ETIM 8:
    EC000228 - Power circuit-breaker for trafo/generator/installation protection
  • Object Classification Code:
    Q
  • UNSPSC:
    39120000
  • WEEE Category:
    5. Small Equipment (No External Dimension More Than 50 cm)
  • eClass:
    V11.1 : 27370409
  • Contact us

    Submit your inquiry and we will contact you

    Contact us
Select region / language

Popular links