Detailed information for: XT1N 160 TMD 100-1000 3p F F

This page contains technical data sheet, documents library and links to offering related to this product. If you require any other information, please contact us using form located at the bottom of the page.

Data Sheet
Downloads
Where to buy online
Related Links

XT1N 160 TMD 100-1000 3p F F

General Information

  • Extended Product Type:
    XT1N 160 TMD 100-1000 3p F F
  • Product ID:
    1SDA067416R1
  • EAN:
    8015644013103
  • Catalog Description:
    XT1N 160 TMD 100-1000 3p F F
  • Long Description:
    C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 100-1000 A

Where Used (as part of "kit")

Identifier Description Type
3HAC058321-001
Circuit breaker, w term. Kit

Ordering

  • E-Number (Finland):
    3640527
  • E-Number (Sweden):
    3182429
  • EAN:
    8015644013103
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362090

Dimensions

  • Product Net Width:
    76.2 mm
  • Product Net Height:
    130 mm
  • Product Net Depth / Length:
    70 mm
  • Product Net Weight:
    1.1 kg

Container Information

  • Package Level 1 Units:
    box 1 piece
  • Package Level 1 Width:
    128 mm
  • Package Level 1 Height:
    135 mm
  • Package Level 1 Depth / Length:
    143 mm
  • Package Level 1 Gross Weight:
    1.133 kg
  • Package Level 1 EAN:
    8015644013103

Environmental

  • RoHS Status:
    Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • Conflict Minerals Reporting Template (CMRT):
    9AKK108467A5658
  • Environmental Information:
    9AKK107991A8215
    9AKK108467A6707
  • REACH Declaration:
    9AKK108466A1425
  • RoHS Information:
    9AKK108466A1424
  • SCIP:
    9dc23701-0389-4d5d-9536-ba4ecc672f9f Italy (IT)
  • Simplified SCIP:
    8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece (GR)
    db9cca29-2669-426f-bf76-0e2f3f91228f Portugal (PT)
    01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria (BG)
    b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden (SE)
    996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland (PL)
    8fd3fa87-f754-4249-8c2f-b59e41939151 France (FR)
    c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden (SE)
    84ac0468-5c88-4c5d-8651-f235b69841f9 Norway (NO)
    fbb53485-dd85-4069-8b43-658e7c5756b5 Finland (FI)
    d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands (NL)
    1a85d563-57df-4b20-b426-89ccb3c219e0 Germany (DE)
    e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark (DK)
    b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany (DE)
    d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia (HR)
    83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland (PL)
    4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany (DE)
    3b489665-c6a7-4f01-ac7f-d84483cd1553 France (FR)
    e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands (NL)
    c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain (ES)
    83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland (PL)
    84ac0468-5c88-4c5d-8651-f235b69841f9 Norway (NO)
    fbb53485-dd85-4069-8b43-658e7c5756b5 Finland (FI)
    b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden (SE)
    2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands (NL)
    996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland (PL)
    8fd3fa87-f754-4249-8c2f-b59e41939151 France (FR)
    c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden (SE)
    8b19cf35-ed11-4fe7-8969-08b832056cec Germany (DE)
    3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic (CZ)
    5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland (PL)
    cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands (NL)
    1216d8d6-e907-4c14-bafd-557686032dbe Netherlands (NL)
    87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia (EE)
    8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece (GR)
    db9cca29-2669-426f-bf76-0e2f3f91228f Portugal (PT)
    8b19cf35-ed11-4fe7-8969-08b832056cec Germany (DE)
    4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany (DE)
    3b489665-c6a7-4f01-ac7f-d84483cd1553 France (FR)
    e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands (NL)
    c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain (ES)
    2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands (NL)
    01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria (BG)
    d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands (NL)
    1a85d563-57df-4b20-b426-89ccb3c219e0 Germany (DE)
    e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark (DK)
    b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany (DE)
    d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia (HR)
    3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic (CZ)
    5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland (PL)
    cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands (NL)
    1216d8d6-e907-4c14-bafd-557686032dbe Netherlands (NL)
    87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia (EE)
  • Toxic Substances Control Act - TSCA:
    9AKK108467A8326

Additional Information

  • Circuit Breaker Type to be Associated:
    Power Distribution
  • Connecting Capacity Main Circuit:
    Busbar 45.5 ... 80 mm²
  • Current Type:
    AC/DC
  • Electrical Durability:
    120 cycles per hour
    8000 cycle
  • Mechanical Durability:
    240 cycles per hour
    25000 cycle
  • Number of Poles:
    3
  • Opening Time:
    CB with SOR 15 ms
    CB with UVR 15 ms
  • Order Multiple:
    1 piece
  • Power Loss:
    at Rated Operating Conditions per Pole 7 W
  • Product Main Type:
    SACE Tmax XT
  • Product Name:
    Moulded Case Circuit Breaker
  • Product Type:
    Automatic Circuit Breaker
  • Rated Current (In):
    100 A
  • Rated Frequency (f):
    50 / 60 Hz
  • Rated Voltage (Ur):
    690 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Rated Instantaneous Short-Circuit Current Setting (Ii):
    1000 A
  • Rated Insulation Voltage (Ui):
    800 V
  • Rated Operational Voltage:
    690 V AC
    500 V DC
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    (220 V AC) 50 kA
    (230 V AC) 50 kA
    (240 V AC) 50 kA
    (380 V AC) 36 kA
    (415 V AC) 36 kA
    (440 V AC) 18 kA
    (500 V AC) 15 kA
    (525 V AC) 11 kA
    (690 V AC) 5 kA
    (250 V DC) 2 Poles in Series 36 kA
    (500 V DC) 3 Poles in Series 36 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    (220 V AC) 65 kA
    (230 V AC) 65 kA
    (240 V AC) 65 kA
    (380 V AC) 36 kA
    (415 V AC) 36 kA
    (440 V AC) 36 kA
    (500 V AC) 30 kA
    (525 V AC) 22 kA
    (690 V AC) 6 kA
    (250 V DC) 2 Poles in Series 36 kA
    (500 V DC) 3 Poles in Series 36 kA
  • Rated Uninterrupted Current (Iu):
    160 A
  • Recommended Screw Driver:
    Main Circuit M6
  • Release:
    TMD
  • Release Type:
    TM
  • RoHS Date:
    NA
  • Setting Range:
    70...100 A
  • Short-Circuit Performance Level:
    N
  • Standards:
    IEC
  • Sub-type:
    XT1
  • Terminal Connection Type:
    Front
  • Terminal Type:
    Bolt
  • Tightening Torque:
    6 N·m
  • Version:
    F
  • CAD Dimensional Drawing:
    1SDH001295R0008

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 5:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 6:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 7:
    EC000228 - Power circuit-breaker for trafo/generator/installation protection
  • ETIM 8:
    EC000228 - Power circuit-breaker for trafo/generator/installation protection
  • Object Classification Code:
    Q
  • UNSPSC:
    39120000
  • WEEE Category:
    5. Small Equipment (No External Dimension More Than 50 cm)
  • eClass:
    V11.1 : 27370409
  • Contact us

    Submit your inquiry and we will contact you

    Contact us
Select region / language

Popular links