Detailed information for: XT1N 160 TMD 125-1250 4p F F InN=100%

This page contains technical data sheet, documents library and links to offering related to this product. If you require any other information, please contact us using form located at the bottom of the page.

Data Sheet
Downloads
Where to buy online
Related Links

XT1N 160 TMD 125-1250 4p F F InN=100%

General Information

  • Extended Product Type:
    XT1N 160 TMD 125-1250 4p F F InN=100%
  • Product ID:
    1SDA067427R1
  • EAN:
    8015644013219
  • Catalog Description:
    XT1N 160 TMD 125-1250 4p F F InN=100%
  • Long Description:
    C.BREAKER TMAX XT1N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 125-1250 A FULLY RATED NEUTRAL

Ordering

  • Order Code US and Canada:
    XT1NE4125AFF000XXX
  • E-Number (Sweden):
    3182422
  • EAN:
    8015644013219
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362090

Dimensions

  • Product Net Width:
    101.6 mm
  • Product Net Height:
    130 mm
  • Product Net Depth / Length:
    70 mm
  • Product Net Weight:
    1.4 kg

Container Information

  • Package Level 1 Units:
    box 1 piece
  • Package Level 1 Width:
    128 mm
  • Package Level 1 Height:
    135 mm
  • Package Level 1 Depth / Length:
    143 mm
  • Package Level 1 Gross Weight:
    1.47 kg
  • Package Level 1 EAN:
    8015644013219

Environmental

  • RoHS Status:
    Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • Conflict Minerals Reporting Template (CMRT):
    9AKK108467A5658
  • Environmental Information:
    9AKK107991A8215
    9AKK108467A6707
  • REACH Declaration:
    9AKK108466A1425
  • RoHS Information:
    9AKK108466A1424
  • SCIP:
    cdfd6e20-4112-43ae-8f11-134bfd1ab102 Italy (IT)
  • Simplified SCIP:
    dc9ed4b0-4027-4417-b38d-af18789f0405 Netherlands (NL)
    b7a5a18c-60bd-4b5e-acd0-87648618cc28 Netherlands (NL)
    eb8a726a-8b4b-4631-aed0-b0cdd1f50426 Estonia (EE)
    1d8e877f-3a56-4783-b21a-169a0f17ad4f Greece (GR)
    6ae9e07a-055f-4a4c-9b68-ac0e2bfe9560 Portugal (PT)
    3b5c1536-61c2-49f4-8719-9f2e21bafa9d Sweden (SE)
    488a34d1-225e-4cce-bb8c-d2429b95a5de Germany (DE)
    f9216198-35f0-4bd5-b779-70d1a835d47b Germany (DE)
    d85d3ee3-733d-43a0-a11e-813a3acec039 France (FR)
    b9d4a66b-1913-47b9-85a1-b40cbe0fd063 Netherlands (NL)
    a4374a46-19a9-4b10-98be-972b95e9258e Spain (ES)
    4228e707-7839-4766-ac09-091a142c4964 Netherlands (NL)
    8b1c242e-e785-479f-841f-31424b75dc1c Bulgaria (BG)
    33028221-6baf-4fbe-83f7-0622b9cfacbd Sweden (SE)
    4228e707-7839-4766-ac09-091a142c4964 Netherlands (NL)
    6ca6c686-4576-4b23-b519-44f4db1823ab Poland (PL)
    58ee00b6-c082-442d-81a4-2c98f2a36859 France (FR)
    3b5c1536-61c2-49f4-8719-9f2e21bafa9d Sweden (SE)
    d24eac56-50db-412d-8109-bab9a5b1ef19 Netherlands (NL)
    6a988071-1b76-4853-8a3c-2eaa88f60c51 Germany (DE)
    df0a279f-528a-43f6-9e9a-26e3aab4e316 Denmark (DK)
    37b2a1b5-4020-4c01-a672-ba47640ee5e3 Germany (DE)
    48eb27f6-1747-49f6-889b-52f84632868a Croatia (HR)
    a30f37c7-12b0-4eb0-b9e3-cc5d6c4b53ed Czech Republic (CZ)
    7633fe0f-9d99-4488-9000-3d20fa34b85e Poland (PL)
    c01187b3-6d26-4d23-9f3d-b6e556bd7197 Poland (PL)
    43bb141e-77f6-4d75-bd62-b3b72a1ca8d5 Norway (NO)
    87d38f84-7a84-4aaf-9a69-7762d9bb6067 Finland (FI)
    488a34d1-225e-4cce-bb8c-d2429b95a5de Germany (DE)
    f9216198-35f0-4bd5-b779-70d1a835d47b Germany (DE)
    d85d3ee3-733d-43a0-a11e-813a3acec039 France (FR)
    b9d4a66b-1913-47b9-85a1-b40cbe0fd063 Netherlands (NL)
    a4374a46-19a9-4b10-98be-972b95e9258e Spain (ES)
    c01187b3-6d26-4d23-9f3d-b6e556bd7197 Poland (PL)
    43bb141e-77f6-4d75-bd62-b3b72a1ca8d5 Norway (NO)
    87d38f84-7a84-4aaf-9a69-7762d9bb6067 Finland (FI)
    d24eac56-50db-412d-8109-bab9a5b1ef19 Netherlands (NL)
    6a988071-1b76-4853-8a3c-2eaa88f60c51 Germany (DE)
    df0a279f-528a-43f6-9e9a-26e3aab4e316 Denmark (DK)
    37b2a1b5-4020-4c01-a672-ba47640ee5e3 Germany (DE)
    48eb27f6-1747-49f6-889b-52f84632868a Croatia (HR)
    a30f37c7-12b0-4eb0-b9e3-cc5d6c4b53ed Czech Republic (CZ)
    7633fe0f-9d99-4488-9000-3d20fa34b85e Poland (PL)
    dc9ed4b0-4027-4417-b38d-af18789f0405 Netherlands (NL)
    b7a5a18c-60bd-4b5e-acd0-87648618cc28 Netherlands (NL)
    eb8a726a-8b4b-4631-aed0-b0cdd1f50426 Estonia (EE)
    1d8e877f-3a56-4783-b21a-169a0f17ad4f Greece (GR)
    6ae9e07a-055f-4a4c-9b68-ac0e2bfe9560 Portugal (PT)
    8b1c242e-e785-479f-841f-31424b75dc1c Bulgaria (BG)
    33028221-6baf-4fbe-83f7-0622b9cfacbd Sweden (SE)
    6ca6c686-4576-4b23-b519-44f4db1823ab Poland (PL)
    58ee00b6-c082-442d-81a4-2c98f2a36859 France (FR)
  • Toxic Substances Control Act - TSCA:
    9AKK108467A8326

Additional Information

  • Circuit Breaker Type to be Associated:
    Power Distribution
  • Connecting Capacity Main Circuit:
    Busbar 45.5 ... 80 mm²
  • Current Type:
    AC/DC
  • Electrical Durability:
    120 cycles per hour
    8000 cycle
  • Mechanical Durability:
    240 cycles per hour
    25000 cycle
  • Number of Poles:
    4
  • Opening Time:
    CB with SOR 15 ms
    CB with UVR 15 ms
  • Order Multiple:
    1 piece
  • Power Loss:
    at Rated Operating Conditions per Pole 10.7 W
  • Product Main Type:
    SACE Tmax XT
  • Product Name:
    Moulded Case Circuit Breaker
  • Product Type:
    Automatic Circuit Breaker
  • Rated Current (In):
    125 A
  • Rated Frequency (f):
    50 / 60 Hz
  • Rated Voltage (Ur):
    690 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Rated Instantaneous Short-Circuit Current Setting (Ii):
    1250 A
  • Rated Insulation Voltage (Ui):
    800 V
  • Rated Operational Voltage:
    690 V AC
    500 V DC
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    (220 V AC) 50 kA
    (230 V AC) 50 kA
    (240 V AC) 50 kA
    (380 V AC) 36 kA
    (415 V AC) 36 kA
    (440 V AC) 18 kA
    (500 V AC) 15 kA
    (525 V AC) 11 kA
    (690 V AC) 5 kA
    (250 V DC) 2 Poles in Series 36 kA
    (500 V DC) 3 Poles in Series 36 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    (220 V AC) 65 kA
    (230 V AC) 65 kA
    (240 V AC) 65 kA
    (380 V AC) 36 kA
    (415 V AC) 36 kA
    (440 V AC) 36 kA
    (500 V AC) 30 kA
    (525 V AC) 22 kA
    (690 V AC) 6 kA
    (250 V DC) 2 Poles in Series 36 kA
    (500 V DC) 3 Poles in Series 36 kA
  • Rated Uninterrupted Current (Iu):
    160 A
  • Recommended Screw Driver:
    Main Circuit M6
  • Release:
    TMD
  • Release Type:
    TM
  • Setting Range:
    87.5...125 A
  • Short-Circuit Performance Level:
    N
  • Standards:
    IEC
  • Sub-type:
    XT1
  • Terminal Connection Type:
    Front
  • Terminal Type:
    Bolt
  • Tightening Torque:
    6 N·m
  • Version:
    F
  • CAD Dimensional Drawing:
    1SDH001295R0080

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 5:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 6:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 7:
    EC000228 - Power circuit-breaker for trafo/generator/installation protection
  • ETIM 8:
    EC000228 - Power circuit-breaker for trafo/generator/installation protection
  • Object Classification Code:
    Q
  • UNSPSC:
    39120000
  • WEEE Category:
    5. Small Equipment (No External Dimension More Than 50 cm)
  • eClass:
    V11.1 : 27370409