Constructions like “Simplex” or “Redundant” are possible and adapts all over your application.

If you want to know more about your FOUNDATION fieldbus-H1 network, the power supply family comes with diagnostic modules and DTMs. The extended information reduces the commissioning and increase the plant availability.

See overview table under “Data” tab


Links
FF Installation suggestion

Data

Power supply family

Simplex
NFP310

(…L0110)

Redundant NFP310

(…L0120)

Motherboard

1x
(Power supply)

1x
(Power supply -Redundant)

Power supply module

max. 4x

max. 4x (+4)

Diagnostic module

1x

1x

Bus termination

4x switchable
(H1 side)

4x switchable
(H1 side)

Host connection

4x

4x (+4)

Ex(Haz) approval

Zone 2 /
Class I, Div. 2

Zone 2 /
Class I, Div. 2

IP type of protection

IP 20

IP 20

Grounding connection set
NGP310(…L0100)

Yes

Yes


Power supply modules

NGP310

(…L0150)

NGP310

(…L0152)

NGP110

Conditioner*
(…L0010)

Power supply family

Yes

Yes

--

H1 power feed (US)

28 … 30 V DC

25…28 V DC

14.7 …30.7 V DC

H1 power feed (IS)

≤ 500 mA

≤ 360 mA

≤ 1 A

Elec. isolation

Yes

Yes

--

Bus termination

--

--

1x switchable
(H1 side)

Ex(Haz) approval

Zone 2 /
Class I, Div. 2

Zone 2 /
Class I, Div. 2

--

IP type of protection

IP 20

IP 20

IP 20

*) NGP110 Conditioner is an individual component and not part of the power supply family.

Diagnostic modules (optional)

NGP312

(…L0160)

NGP312

(…L0161)

Checking of the
- power source
-power supply modules
- H1 overload & short circuit
- Physical layer

Yes
Yes
Yes
--

Yes
Yes
Yes
Yes

Message transmission via

Relay contact

Contact
and Diagnostic bus

Diagnostic gateway mandatory

(See below)

--

Yes

DTMs mandatory

(See below)

--

Yes

Address assignment
(optional)

--

DIP switch
(for the Diagnostic bus)

Ex(Haz) approval

Zone 2 /
Class I, Div. 2

Zone 2 /
Class I, Div. 2

IP type of protection

IP 20

IP 20

 

Diagnostic gateway module (optional)

NGP312

(…L0181)

NGP312

(…L0182)

TCP/IP

(100 BASE-TX)

1x

1x

Diagnostic bus

2x

2x

Observation of

2x
31 (8) Power supply motherboards

2x
31 (8) Power supply motherboards

Ex(Haz) approval

Zone 2

Zone 2

IP type of protection

IP 20

IP 20

Terminal block  -- 8 inputs & 3 outputs 

Diagnostic bus connection cable
6 cm

NGP312(…L0190)

Yes

 --

 

DTMs (optional)
Attention: First check that the DTMs have been approved for your frame application!

Diagnostic gateway

FDS-DTM Server

(free-of-charge)

Diagnostic DTM

DTM-FC.AD

(free-of-charge)

Diagnostic DTM

NGP312

(…L0170)

Diagnostic DTM

NGP312
(…L0171)

Mandatory for Diagnostic transmission via bus

Yes

Yes

(one of the three Diagnostic DTMs is mandatory)

Diagnostic DTM
- Basic

- Pro ≤100 segments

- Pro >100 segments

 

--

--

--

 

Yes

--

--

 

--

Yes

--

 

--

--

Yes

Windows 7, Vista and XP
(64/32 bit version)

Yes

Yes

Yes

Yes

Dialog language English

Yes

Yes

Yes

Yes

 